<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>LPE - logicalplanet</title>
	<atom:link href="https://www.logicalplanet.com/tag/lpe/feed/" rel="self" type="application/rss+xml" />
	<link>https://www.logicalplanet.com</link>
	<description>making ideas, one layer at a time</description>
	<lastBuildDate>Wed, 18 Dec 2024 20:33:58 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9.4</generator>

<image>
	<url>https://www.logicalplanet.com/wp-content/uploads/2024/02/cropped-LP240220e-5-512x512-Large-Favicon-100-32x32.jpg</url>
	<title>LPE - logicalplanet</title>
	<link>https://www.logicalplanet.com</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Double Flap Through Wall Vent</title>
		<link>https://www.logicalplanet.com/2024/12/06/thru_wall_vent-2/</link>
					<comments>https://www.logicalplanet.com/2024/12/06/thru_wall_vent-2/#respond</comments>
		
		<dc:creator><![CDATA[Paul Brock]]></dc:creator>
		<pubDate>Fri, 06 Dec 2024 22:14:14 +0000</pubDate>
				<category><![CDATA[3d Printing]]></category>
		<category><![CDATA[Replacement]]></category>
		<category><![CDATA[Snap-together]]></category>
		<category><![CDATA[Tools]]></category>
		<category><![CDATA[exhaust]]></category>
		<category><![CDATA[LPE]]></category>
		<category><![CDATA[vent]]></category>
		<category><![CDATA[venting]]></category>
		<guid isPermaLink="false">https://www.logicalplanet.com/?p=2681</guid>

					<description><![CDATA[<p>My exhaust system parts are now a fairly comprehensive system (albeit broken into several different postings &#8211; one day I will compile them all together) for exhausting machines to the outside but until now I have not posted a through-wall system. Here it is&#8230; This through-wall venting port has two flap sets so that it [&#8230;]</p>
<p>The post <a href="https://www.logicalplanet.com/2024/12/06/thru_wall_vent-2/">Double Flap Through Wall Vent</a> first appeared on <a href="https://www.logicalplanet.com">logicalplanet</a>.</p>]]></description>
										<content:encoded><![CDATA[<p>My exhaust system parts are now a fairly comprehensive system (albeit broken into several different postings &#8211; one day I will compile them all together) for exhausting machines to the outside but until now I have not posted a through-wall system.  Here it is&#8230;</p>



<figure class="wp-block-image size-large"><img fetchpriority="high" decoding="async" width="839" height="1024" src="https://www.logicalplanet.com/wp-content/uploads/2024/12/241122_01-Thangs-50-839x1024.jpg" alt="" class="wp-image-2730" srcset="https://www.logicalplanet.com/wp-content/uploads/2024/12/241122_01-Thangs-50-839x1024.jpg 839w, https://www.logicalplanet.com/wp-content/uploads/2024/12/241122_01-Thangs-50-246x300.jpg 246w, https://www.logicalplanet.com/wp-content/uploads/2024/12/241122_01-Thangs-50-768x937.jpg 768w, https://www.logicalplanet.com/wp-content/uploads/2024/12/241122_01-Thangs-50.jpg 1200w" sizes="(max-width: 839px) 100vw, 839px" /></figure>



<figure class="wp-block-embed is-type-video is-provider-youtube wp-block-embed-youtube wp-embed-aspect-16-9 wp-has-aspect-ratio"><div class="wp-block-embed__wrapper">
<iframe title="Through Wall Vent" width="500" height="281" src="https://www.youtube.com/embed/Vcx7PmhGwc8?feature=oembed" frameborder="0" allow="accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share" referrerpolicy="strict-origin-when-cross-origin" allowfullscreen></iframe>
</div></figure>



<span id="more-2681"></span>



<figure class="wp-block-image size-large"><img decoding="async" width="839" height="1024" src="https://www.logicalplanet.com/wp-content/uploads/2024/12/241122_02-Thangs-50-839x1024.jpg" alt="" class="wp-image-2731" srcset="https://www.logicalplanet.com/wp-content/uploads/2024/12/241122_02-Thangs-50-839x1024.jpg 839w, https://www.logicalplanet.com/wp-content/uploads/2024/12/241122_02-Thangs-50-246x300.jpg 246w, https://www.logicalplanet.com/wp-content/uploads/2024/12/241122_02-Thangs-50-768x937.jpg 768w, https://www.logicalplanet.com/wp-content/uploads/2024/12/241122_02-Thangs-50.jpg 1200w" sizes="(max-width: 839px) 100vw, 839px" /></figure>



<p>This through-wall venting port has two flap sets so that it is &#8220;double insulated&#8221; and more resistant to insects and other would-be assailants.  I have been using this for a year or so but only now just posting it as I have had several requests recently.  </p>



<figure class="wp-block-image size-large"><img decoding="async" width="839" height="1024" src="https://www.logicalplanet.com/wp-content/uploads/2024/12/241122_03-Thangs-50-839x1024.jpg" alt="" class="wp-image-2732" srcset="https://www.logicalplanet.com/wp-content/uploads/2024/12/241122_03-Thangs-50-839x1024.jpg 839w, https://www.logicalplanet.com/wp-content/uploads/2024/12/241122_03-Thangs-50-246x300.jpg 246w, https://www.logicalplanet.com/wp-content/uploads/2024/12/241122_03-Thangs-50-768x937.jpg 768w, https://www.logicalplanet.com/wp-content/uploads/2024/12/241122_03-Thangs-50.jpg 1200w" sizes="(max-width: 839px) 100vw, 839px" /></figure>



<p>The idea is that on the outside wall, you mount a 4&#8243; duct plate that connects to a 4&#8243; pipe through the wall, and onto which the double-flapped vent mounts.  </p>



<figure class="wp-block-image size-large"><img decoding="async" width="839" height="1024" src="https://www.logicalplanet.com/wp-content/uploads/2024/12/241122_04-Thangs-50-839x1024.jpg" alt="" class="wp-image-2733" srcset="https://www.logicalplanet.com/wp-content/uploads/2024/12/241122_04-Thangs-50-839x1024.jpg 839w, https://www.logicalplanet.com/wp-content/uploads/2024/12/241122_04-Thangs-50-246x300.jpg 246w, https://www.logicalplanet.com/wp-content/uploads/2024/12/241122_04-Thangs-50-768x937.jpg 768w, https://www.logicalplanet.com/wp-content/uploads/2024/12/241122_04-Thangs-50.jpg 1200w" sizes="(max-width: 839px) 100vw, 839px" /></figure>



<p>On the inside, another 4&#8243; duct plate, which connects to the other end of the pipe through the wall, and, on to which you can mount a variety of headers and or an inline fan to assist the exhaust system.  </p>



<p>As you have probably seen from my earlier postings, I like having negative pressure in my exhaust system to ensure no leakage and assist the exhaust fans on my various printers.  In this case, I have designed it for a low-cost 120x120x25mm inline fan.  </p>



<figure class="wp-block-image size-large"><img decoding="async" width="839" height="1024" src="https://www.logicalplanet.com/wp-content/uploads/2024/12/241122_08-Thangs-50-839x1024.jpg" alt="" class="wp-image-2734" srcset="https://www.logicalplanet.com/wp-content/uploads/2024/12/241122_08-Thangs-50-839x1024.jpg 839w, https://www.logicalplanet.com/wp-content/uploads/2024/12/241122_08-Thangs-50-246x300.jpg 246w, https://www.logicalplanet.com/wp-content/uploads/2024/12/241122_08-Thangs-50-768x937.jpg 768w, https://www.logicalplanet.com/wp-content/uploads/2024/12/241122_08-Thangs-50.jpg 1200w" sizes="(max-width: 839px) 100vw, 839px" /></figure>



<p>The inside headers are designed to work with my quick-connect exhaust and other components so you can build out the system however you choose.</p>



<p class="has-large-font-size"><strong>Printing</strong></p>



<p>Functional designs (such as this one) generally require more strength than non-functional designs and more strength than the typical default slicer settings provide, so please review your slicer settings carefully.</p>



<p>This product was designed for a 0.4mm nozzle, a 0.2mm layer height and the following settings:</p>



<ul class="wp-block-list">
<li>Wall Line Count = 4 ( 4 x 0.4mm = 1.6mm walls )</li>



<li>Top and Bottom Layer Count = 5 ( 5 x 0.2mm = 1.0mm top and bottom )</li>



<li>Infill = 40%, Cubic</li>



<li>Ironing = OFF (not needed)</li>



<li>Wall Generator: Arachne (If you are using Cura this is automatically enabled by default)</li>



<li>Detect Thin Walls = Not needed but good to keep ON</li>



<li>Support = NO, all required support is designed into this product</li>



<li>Brim = NO </li>



<li>MATERIAL: ASA or PETG recommended </li>



<li>PRINT ORIENTATION: As per the STL files</li>
</ul>



<p class="has-large-font-size"><strong>Assembly Notes</strong></p>



<p>Please refer to my video for assembly instructions and other notes.</p>



<p class="has-large-font-size"></p><p>The post <a href="https://www.logicalplanet.com/2024/12/06/thru_wall_vent-2/">Double Flap Through Wall Vent</a> first appeared on <a href="https://www.logicalplanet.com">logicalplanet</a>.</p>]]></content:encoded>
					
					<wfw:commentRss>https://www.logicalplanet.com/2024/12/06/thru_wall_vent-2/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
	</channel>
</rss>
